Close
Select your language

The page doesn't exist in this language

Find your Coloplast country website

Female Urinary Incontinence

Urinary incontinence, whether caused by urethral hypermobility, intrinsic sphincter disorder, or an overactive bladder is a significant health and quality-of-life concern for women around the world. Fortunately, there are a wide variety of treatment options available. The most appropriate type of procedure will depend on the type and severity of the patient’s incontinence.

Coloplast offers a broad portfolio of treatment options so physicians and patients can work together to determine the best course of treatment for each individual situation.

All  options should be discussed with the patient to determine the best option for them.
Read more about Coloplast’s treatment options for stress urinary incontinence. 

Altis Single Incision Sling

Precise Placement. Proven Sling Material. Dynamic Adjustability.

Altis allows for a less invasive approach for transobturator placement. Consistent placement with less mesh left behind. Meet the next generation in mini-slings. Learn more
Close

Even Less is More

The Altis single incision sling is an innovative next generation technology from Coloplast. Altis is both less invasive at implant and leaves less mesh behind, but is based on the proven product legacy of the Aris TO and Supris Sling Systems. Altis provides ease of use and reproducibility based on the introducer, anchors and sling material. The dynamic adjustability of the sling allows for accurate tensioning and placement of the sling in relation to the urethra. Like Aris and Supris, Altis is a low elasticity sling. Low elasticity and secure anchoring means what you see is what you get - potentially taking the guess - work out of tensioning and placement, positioning the sling without compression under the urethra.

 

With Altis even less is more.

 

The Altis Single Incision Sling System is indicated for the treatment of female stress urinary incontinence (SUI) resulting from urethral hypermobility and/or intrinsic sphincter deficiency (ISD).

 

Click here for more product information

Close

Altis Clinical Results

12 Month IDE Clinical Study Summary: Altis was the first single incision sling to complete an Investigational Device Study prior to market availability. Learn more about how Altis can make a difference in the lives of patients. See Results

The IDE clinical study of the Altis Single Incision Sling System is a prospective, single arm, non-randomized study. Study was conducted at 17 clinical sites in women with confirmed SUI, with follow-up through 2 years. 112 female subjects with SUI were successfully implanted with the Altis device. Outcomes data is below.

Click to download a PDF of the full summary.

Outcomes Data

Endpoint Measurement 6 Months 12 Months
Pad Weight (PW)    50% Reduction    85.4% (88/103)    90.1% (91/101)   
Cough Stress Test (CST)    % Success in both standing &    
lithotomy positions
92.2% (95/103)    90.1% (91/101)  
Patient Global Impression of    
Improvement (PG-I) 
% Very much or much better    87.6% (92/105)    89.3% (92/103
Close
Patient Education

Patient Education

A fully informed decision is the best decision. Nothing can take the place of a your discussions with your patients, but we can support you as you guide patients' treatment path. Connect to resources

Coloplast has educational resources available for you to use with patients. Resouces are available online for easy access. 

  • PelvicHealthID.com is a general women's pelvic health site sponsored by Coloplast with non-product specific information on anatomy, pelvic organ prolapse, stress urinary incontinence, and the many treatment options. Women can find stories from other women like them.
  • The Altis Patient Education brochure PDF can be downloaded here (6MB).  Printed versions of this and other patient brochures and educational resources can be ordered through your Coloplast Representative.
Close
But Do the Anchors Hold?

But Do the Anchors Hold?

It is one of the first questions from those who have used other mini slings. View the study
Close

Altis Rabbit Model Evaluation

Altis has been evaluated in rabbit models evaluating the pull out forces compared to other single incision slings. Altis shows favorable results compared to currently marketed mini slings in the push in and pull out forces. And helical-type introducers mean reproducible placement for secure anchoring time after time.

Close

Supris

Experience the difference.

The low density and elasticity of Supris may result in less banding for predictability and accuracy when tensioning. Learn more
Close

Less is More

The Supris sling is light. In fact, it is the lightest and thinnest on the market which means less material implanted. The Supris sling closely mimics the low elasticity of natural collagen fibers and may reduce cording or banding and support  placement and  tensioning.

 

The Supris Sling System is an implantable, sub-urethral, support tape indicated for the surgical treatment of all types of stress urinary incontinence (SUI), for female urinary incontinence resulting from urethral hypermobility and/or intrinsic sphincter deficiency. 

 

Click here for more product information

Close

Supris Clinical Results

Learn more

Supris Retropubic Sling System offers low elasticity to support tensioning and positioning of the sling. Learn more about clinical results here.

 

Download a PDF of the "Tine-Free, Sheath-Free, Inelastic Retropubic Sling (Supris) for Stress Urinary Incontinence" Poster

Close
Patient Education

Patient Education

A fully informed decision is the best decision. Nothing can take the place of a your discussions with your patients, but we can support you as you guide patients' treatment path. Connect to resources

Coloplast has educational resources available for you to use with patients. Resouces are available online for easy access. Hard copies of brochures can obtained by contacting your Coloplast representative.

  • PelvicHealthID.com is a general women's pelvic health site sponsored by Coloplast with non-product specific information on anatomy, pelvic organ prolapse, stress urinary incontinence, and the many treatment options. Women can find stories from other women like them.
  • The Coloplast Stress Urinary Incontinence Patient Education brochure PDF can be downloaded here.  Printed versions of this and other patient brochures and educational resources can be ordered through your Coloplast Representative.
Close

Aris

Simplified. Safe. Effective.

Experience the difference. The low density and elasticity of Aris may result in less banding for predictability and accuracy when tensioning. Learn more
Close

Less is More

The Aris sling is light. The Aris sling closely mimics the low elasticity of natural collagen fibers and may reduce cording or banding to support placement and ease of tensioning.

 

Aris is an implantable, suburethral, support tape indicated for the surgical treatment of all types of stress urinary incontinence (SUI), for female urinary incontinence resulting from urethral hypermobility and/or intrinsic sphincter deficiency.

 

Click here for more product information

Close

Aris Clinical Results

Learn more

Aris Transobturator Sling System  low elasticity allows for easy tensioning and positioning of the sling.

 

Download a PDF of "Aris Transobturator Sling: Three Years Follow-Up" poster by Saad Juma and C. Gilberto Brito

Close
Patient Education

Patient Education

A fully informed decision is the best decision. Nothing can take the place of a your discussions with your patients, but we can support you as you guide patients' treatment path. Connect to resources

Coloplast has educational resources available for you to use with patients. Resouces are available online for easy access. Hard copies of brochures can obtained by contacting your Coloplast representative.

  • PelvicHealthID.com is a general women's pelvic health site sponsored by Coloplast with non-product specific information on anatomy, pelvic organ prolapse, stress urinary incontinence, and the many treatment options. Women can find stories from other women like them.
  • The Coloplast Stress Urinary Incontinence Patient Education brochure PDF can be downloaded here.  Printed versions of this and other patient brochures and educational resources can be ordered through your Coloplast Representative.
Close

BoNee Bladder Injection Needle

Reliable and Accurate

BoNee bladder injection needle for precise placement and delivery Learn more
Close

Reliable and Accurate

The Coloplast BoNee bladder injection needle, developed in partnership with doctors, delivers low viscosity medication exactly where it is intended.
Reliable and accurate:

  • 4 mm tip needle suitable for penetration of the bladder wall
  • Needle protection cap to prevent damage
  • Small (22 gauge) needle size to reduce bleeding, tissue damage and pain
  • Flexible and strong 5 FR body to reduce kinking

The Bonee needle is used to deliver injectable materials into the urinary bladder wall during the transurethral endoscopic procedures.

Close
Close

Free Sample - Free Shipping

Thank you for your order

Receipt

View desktop version